Dell Server

From AlphaBook
Revision as of 13:00, 18 September 2018 by Admin (talk | contribs) (RAID 1)
Jump to: navigation, search

Lost package when ping iDRAC IP address

  • iDRAC may not work properly on 10/100/1000M Auto mode
  • Set 100M on switch port manually

racadm

  • racadm -r 192.168.0.20 -u root -p xxx get BIOS.SysInformation.SystemServiceTag
  • racadm -r 192.168.0.20 -u root -p xxx get BIOS.SysInformation. SystemModelName
  • racadm -r 192.168.0.20 -u root -p xxx get System.LCD.CurrentDisplay
  • racadm -r 192.168.0.20 -u root -p xxx serveraction powerup
  • racadm -r 192.168.0.20 -u root -p xxx serveraction powerdown
  • racadm -r 192.168.0.20 -u root -p xxx serveraction powercycle
  • racadm -r 192.168.0.20 -u root -p xxx serveraction powerstatus

RAID 1

  • RAID 1 consists of an exact copy (or mirror) of a set of data on two or more disks; a classic RAID 1 mirrored pair contains two disks.

RAID 5

RAID 5 + Hotspare